Your location:
The pneumatic reversible fan turns its blades with compressed air, so the airflow can be reversed to clear a radiator or cooler core where no hydraulic circuit is available.
The pneumatic reversible fan is a complete air-moving assembly — blades, hub and pneumatic actuator — for engine and cooler cooling on machinery that has compressed air but no convenient hydraulic supply. The blade angle is turned by air pressure, so the flow reverses on demand and the core is blown clean in place.
Blades are moulded in PAG, in conductive PAGAS where static discharge has to be avoided, or cast in aluminium ADC12 for high-temperature duties. Each fan is assembled and balanced before shipment, and blades, hubs and actuators are available as service parts.
Pneumatically reversed airflow — cooling cores are cleaned in place using the machine air supply
Diameter range 600-1176 mm with 9 blades, quoted against the fan ring of the machine
Blade materials: PAG, conductive PAGAS and die-cast aluminium ADC12
No hydraulic circuit required — the reversal works from compressed air
Balanced as a complete fan before shipment for low vibration and bearing load
| Item | Specification |
|---|---|
| Model | Pneumatic Reversible Fan |
| Type | Reversible axial fan (pneumatically actuated blade reversal) |
| Diameter range | 600-1176 mm |
| Blade count | 9 |
| Hub | Pneumatic reversible hub (compressed-air actuator) |
| Blade materials | PAG / conductive PAGAS / ALU (ADC12) |
| Balancing | Dynamic balancing as a complete fan before shipment |
| Applications | Engine radiator cooling, cooler cleaning, industrial air movement |
| Material | Composition | Temperature range | Typical duty |
|---|---|---|---|
| PAG | PA6 with 30% glass fibre | -40 °C to 110 °C | General heavy-load blade |
| PAGAS | PA6 with 15% carbon fibre and 15% glass fibre (conductive) | -30 °C to 100 °C | Dust and gas atmospheres where static discharge must be avoided |
| ALU | Die-cast aluminium ADC12 | -40 °C to 150 °C, short-term 300 °C for 2 h | High-temperature zones |
The Pneumatic Reversible Fan belongs to the P Series range. The related pages are hydraulic reversible fan, industrial axial fan blades, industrial axial fan impellers.
For the complete fan version of this blade, including the assembled fan and its application pages, see the Pneumatic Reversible Fan complete fan page. This page covers the Pneumatic Reversible Fan blade and impeller side — replacing a blade set, matching the hub and reproducing the original duty point.
Support starts before the blade is quoted. The points below are the ones that decide whether an Pneumatic Reversible Fan fits an existing fan or a new cooling pack, and they are the same checks used for OEM programs and retrofit work.
Diameter — set by the fan ring or shroud that is available, since this fixes the achievable air volume at the working speed
Airflow and static pressure — the duty point the fan has to meet at the working speed
Blade count — raised for pressure and lower airflow, lowered for maximum air volume and lower blade-passing noise
Material — decided by the maximum air temperature and by whether static discharge has to be avoided
Hub and shaft interface — confirmed before the blade set is released for production
Selection follows that order because changing a later step normally means going back to the first: blade count and hub rating both limit what a given diameter can carry at the working speed.
A replacement does not have to match a drawing, only the interface that already exists on the machine:
Connection holes and bushings are machined to match the existing hub, so the blade set can be fitted
The blade count and blade type of the original fan are confirmed, which preserves the original airflow and noise level
The hub family is verified against the shaft, including the taper bush where one is used
The assembled impeller is balanced before shipment, so no balancing rig is needed on site
Every impeller is balanced on a hand laser balancing machine before shipment. On a large-diameter blade this matters more than on a small one, because imbalance grows with diameter and blade mass and shows up as vibration, fastener loosening and bearing wear. Balance settings and blade count are recorded so a later replacement can be matched to the same condition.
Blade count, blade profile, pitch setting, hub family and material can all be fixed for an OEM program, and an existing fan can be reviewed when the cooling pack or the ventilation duty is revised:
Blade count and pitch angle set to the required airflow and pressure
Hub and shaft interface matched to the existing drive
Material selected against temperature and atmosphere (PAG, conductive PAGAS, ALU)
Replacement programs where only the blades are renewed and the hub stays in service
Material and test records are available for projects that require them: certificate of analysis for the material and for the finished PAGAS blade, UV resistance and fire behaviour reports for PAG, and explosion-proof type test reports where conductive blades are used in a classified atmosphere. Certificate and report copies are provided on request rather than published as current certifications.
The drawings below are the ones used for the Pneumatic Reversible Fan blade and hub interface. They are kept on this page because they answer the questions that come up most often when a blade set is being matched to an existing fan.

Engineering drawing supplied for review; dimensions are confirmed against the fan before production.

Engineering drawing supplied for review; dimensions are confirmed against the fan before production.

Engineering drawing supplied for review; dimensions are confirmed against the fan before production.

Engineering drawing supplied for review; dimensions are confirmed against the fan before production.

Engineering drawing supplied for review; dimensions are confirmed against the fan before production.
The Pneumatic Reversible Fan is specified where a large air volume has to be moved continuously with moderate pressure: applications where a large slow impeller is more efficient and quieter than a smaller fast fan. The duties below are the ones this blade is normally ordered for.
Engine radiator and cooler cooling where no hydraulic supply is available
In-place core cleaning on mobile machinery
Industrial air movement and HVAC duties in the 600-1176 mm class
Replacement of a worn pneumatic reversible fan
| Application | Duty characteristic | Diameter | Blades | Hub | Material |
|---|---|---|---|---|---|
| Engine cooling | Machinery with compressed air on board | 600-1176 mm | 9 | Pneumatic reversible | PAG / ALU |
| Core cleaning | Reversed flow blows the core clean in place | 600-1176 mm | 9 | Pneumatic reversible | PAG / ALU |
| Industrial air movement | HVAC and process air | 600-1176 mm | 9 | Pneumatic reversible | PAG / ALU |
| Service / retrofit | Replacing a worn fan on site | Measured on site | As original | As original | As original |
The matrix is a starting point rather than a final specification: diameter is confirmed against the installation, then blade count and material are fixed against the duty point and the air temperature.
Most orders for this blade are replacements rather than new fans, and they follow the same pattern:
A large fan in a cooling tower or moving-air unit fails, and the hub and shaft are still serviceable
The original diameter and blade count are confirmed from the fan records or measured on site
Connection holes and bushings are machined to the existing hub so the blade set fits without modification
The replacement impeller is balanced before shipment and the fan returns to service without on-site balancing
Where the whole hub has to be renewed, the hub is matched to the existing shaft instead
Because the blade family is unchanged in production, a fan commissioned years ago can be re-bladed to the same airflow and noise condition, which keeps a fleet of machines on one specification.
Installation and commissioning support covers the practical points: blade angle set at assembly, hub clamping and fastener checks, and confirmation that the fan reaches its duty point after the machine is back in service. Field installation for this blade is shown in the product video on the Product Features tab.
The case material below was compiled from the original page and is kept because it documents the machines the Pneumatic Reversible Fan fan has been used on.
![]() | ![]() | ![]() | ![]() |
![]() | ![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
UTEK-DELE (Changzhou Dele Ventilation and Heat Dissipation Technology Co., Ltd.) designs and manufactures axial fan blades, impellers and complete fan assemblies. The range covers moulded PAG and conductive PAGAS blades, die-cast aluminium blades, hubs from H-6 to H-12 and the Z and W families, and finished impellers from 180 mm up to 2200 mm for engine cooling, cooling towers and industrial ventilation.
Production, balancing and inspection are carried out in house, which is what makes a replacement blade or impeller behave like the part it replaces: the same blade geometry, the same hub interface and the same balancing record are reproducible years after the original fan was built.
Blade moulding, hub machining, assembly and packing are handled under one roof, so a fan specification can be reviewed end to end before it is released for production.
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
The equipment that decides fan quality is the balancing and test equipment, because imbalance and airflow errors are what a customer feels in service.
![]() Dynamic Balancing Equipment | ![]() Dynamic Balancing Equipment | ![]() Dynamic Balancing Equipment |
![]() Cutting Machine Equipment | ![]() Cutting Machine Equipment | ![]() Wind Tunnel Laboratory |
The blade and reversible fan designs are protected by granted Chinese patents, and the company operates under ISO9001 and ISO14001 management systems. Certificate and report images are shown below; document copies and validity dates are available on request.
![]() Patent Certificate — Explosion-proof Fan Blade | ![]() Patent Certificate — Variable Pitch Reversible Fan | ![]() Patent Certificate — Adjustable Blade Angle Fan |
![]() ISO9001 | ![]() ISO14001 |
Material behaviour is documented per batch: UV resistance and fire behaviour for PAG, explosion-proof type testing for conductive PAGAS, and certificate of analysis for the material and for the finished PAGAS blade.
![]() UV Resistance Report | ![]() Explosion-proof Type Report | ![]() PAG Material Fire Proof |
![]() Materials Certificate of Analysis | ![]() PAGAS Blade COA |
Support covers the whole life of the fan rather than the shipment alone: duty review before ordering, fitting and replacement advice after delivery, and the documentation needed to keep an installation compliant.
Because blades, hubs and complete impellers are made in the same workshop, a spare part can be reproduced against the original blade count, hub family and pitch setting — the values that decide whether a replacement behaves like the fan it goes into.
Blades and hubs are packed so that the blade profile and the hub bore arrive undamaged, then crated or palletised for the transport mode agreed for the order.
![]() | ![]() | ![]() |
![]() | ![]() | ![]() |
A replacement is normally quoted from a few details rather than a drawing:
Diameter and blade count of the fan being replaced, plus the hub family if it is known
Connection holes and bushings — these are machined to match the existing hub so the part can be fitted
Working speed and duty point, so the pitch angle can be set before shipment
Environment: maximum air temperature and whether a conductive blade material is required
Documentation for material and test records (certificate of analysis, UV, fire and explosion-proof reports) where the project requires it
Where only the blades are worn, a blade set can be supplied against the existing hub instead of a complete impeller, and where the shaft interface has changed, the hub can be matched to the new drive. Technical questions are answered against the fan records so the answer stays valid for the whole machine fleet.
The questions below are answered for this product; the same support applies to its spare blades and hubs.
The blade angle is turned by a compressed-air actuator, so the fan can push air in either direction. Reversing the flow clears dust and chaff from the radiator or cooler core in place.
Blades are built across 600-1176 mm with 9 blades; the exact size is quoted against the fan ring and shaft of the machine.
No. The reversal works from compressed air, which makes it suitable for machines without a convenient hydraulic supply.
PAG (-40 °C to 110 °C), conductive PAGAS (-30 °C to 100 °C) and die-cast aluminium ADC12 (up to 150 °C, short-term 300 °C for 2 hours).
Both. Complete assemblies (blades, hub, actuator) are supplied for new builds, and individual blades, hubs and actuators are supplied as service parts.
Yes. Diameter, blade count, blade angle and the mounting interface are confirmed from the existing machine, and the replacement is balanced before shipment.