Your location :Home  /  Products  / 
Fixed-Angle Fan Blades

Fixed-Angle Fan Blades

Fixed-angle fan blades are moulded with the blade pitch set by the tool: the impeller is supplied ready to mount, with no pitch mechanism to adjust in service. UTEK-DELE builds them in the 180-745 mm range on H family hubs, in PAG, PAGAS or ALU.

Fixed-Angle Fan Blades — UTEK-DELE Axial Fan Range

A fixed-angle fan blade has its pitch built into the mould. The blade cannot be adjusted after assembly, which removes the pitch mechanism, the locking hardware and the setting procedure from the fan. On machines where the cooling requirement is known and stable, that simplification is the point: fewer parts, less to service, and a repeatable impeller every time a blade set is replaced.

UTEK-DELE manufactures fixed-angle blades as the H Series, covering the 180-745 mm class with five to twelve blades on H-6, H-8, H-10 and H-12 hubs. Blade material is chosen from the working temperature and atmosphere, so the same blade geometry can be supplied in moulded PAG, conductive PAGAS or die-cast aluminium for high-temperature zones.

Model Range and Specifications

ModelBlade typeBlade countDiameter rangeBlade materialsHub optionsProduct page
P3HFixed angle5-12180-745 mmPAG / PAGAS / ALUH-6 / H-8 / H-10P3H fixed angle fan
S14HFixed angle5-12180-700 mmPAG / PAGAS / ALUH-6 / H-8 / H-10S14H fixed angle fan
S16HFixed angle5-12180-700 mmPAG / PAGASH-8 / H-10 / H-12S16H fixed angle fan
S1HFixed angle5-12180-700 mmPAG / PAGAS / ALUH-6 / H-8S1H sickle blade fan
1XL / 2HFixed angleQuoted per projectQuoted per projectPAG / PAGAS / ALUH familyQuoted on request

Fixed-angle blades are the standard choice for high-volume machine platforms, because the impeller can be released for production once the duty point is confirmed and no pitch setting is needed on the assembly line.

Blade Materials and Temperature Range

Blade material is selected from the working temperature and from the atmosphere around the impeller:

MaterialCompositionTemperature rangeTypical duty
PAGPA6 with 30% glass fibre-40 °C to 110 °CHeavy-load cooling, anti-aging, general engine cooling
PAGASPA6 with 15% carbon fibre and 15% glass fibre (conductive)-30 °C to 100 °CDust and gas atmospheres where static discharge must be avoided
ALUDie-cast aluminium ADC12-40 °C to 150 °C, short-term 300 °C for 2 hHigh-temperature and fire-resistance zones

The conductive PAGAS option is supplied for equipment working in explosive-risk atmospheres such as dust or gas. It addresses the working environment of the blade; machine-level certification remains the responsibility of the equipment builder.

Hub Options

Blades are supplied with matched hub sets. The hub carries the blade loads and sets the shaft interface, so it is selected together with the blade count:

Hub typeWeightHub diameter
HUB H-60.27 kg / set96 mm
HUB H-80.41 kg / set133 mm
HUB H-100.57 kg / set172 mm
HUB H-120.805 kg / set206 mm

Typical Applications

This series is normally specified for the following duties:

  • Engine radiator cooling on tractors and construction machinery

  • Engine cooling in narrow engine bays with limited shroud clearance

  • Agricultural machinery working in dust and high ambient temperature

  • Replacement blade sets for existing fixed-angle fan assemblies

Specification Support

When a fan is being specified or replaced, the following points are confirmed before a blade set is released. They are the same checks used for OEM programs and for retrofit projects.

  • Duty point: airflow and static pressure required at the working speed, taken from the cooling pack or ventilation requirement

  • Installation: available diameter, shroud clearance, mounting pattern and the shaft interface of the existing hub

  • Environment: maximum air temperature, dust or gas atmosphere, and whether static discharge has to be avoided

  • Drive: available power, belt or direct drive, and whether the fan has to reverse in service

  • Service: blade weight for handling during maintenance and spare-part availability across the machine fleet

Blade count, profile and material are then matched to those conditions in a fixed order: material first, then blade count, then hub family, with diameter confirmed against the shroud. Working in that sequence keeps the mechanical interface stable when the duty requirement changes later in the project, and it is why the same blade family can often stay in production while the cooling pack is revised.

Quality Assurance and Dynamic Balancing

Fixed-angle blades are moulded to a controlled geometry, then assembled with a matched H family hub and balanced on a hand laser balancing machine before shipment. Because the pitch is set by the tool, a replacement blade reproduces the original impeller without a setting procedure in the field.

Customization and Series Overview

Blade count, blade profile, hub family and material can be customized for OEM programs, and existing fans can be reviewed when airflow, noise or durability has to be improved on a running machine. Where the duty point changes with operating conditions, an adjustable-angle blade is the better match; fixed-angle blades are specified when the cooling requirement is stable and service simplicity matters most.

Related ranges: H Series small impellers | PMAX Series high pressure fans | 4XR Series aluminium blades | P Series adjustable fans.

Fixed-Angle Fan Blades — Products in This Family

The blade models below are produced in this blade family. Each product page covers the specifications, materials and replacement details; blade sets are quoted with the hub so the shaft interface is confirmed at the same time.

ModelProduct pageDiameterBlade countHub
P3HP3H Fixed Angle Axial Fan Blade173-745 mm5-12 bladesH-6 / H-8 / H-10
S14HS14H Fixed Angle Axial Fan Blade180-700 mm5-12 bladesH-6 … H-12
S16HS16H Fixed Angle Axial Fan Blade180-700 mm5-12 bladesH-6 … H-12
S1HS1H Fixed Angle Axial Fan Blade180-700 mm5-12 bladesH-6 … H-12
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message