PMAX3 Cooling Package Comparison Worksheet
Use this worksheet to compare a proposed PMAX3 complete axial fan impeller with an existing cooling assembly or a second proposal for the same machine. The worksheet records the hub and impeller configuration, the surrounding air path and the operating point on one reference sheet. It is intended for an engine or radiator package review, where the same nominal fan diameter can be installed next to very different inlets, cores, guards and outlets.
Define the comparison before requesting a curve
Pick a machine, operating mode and drawing revision. Assign a distinct reference to each air-path layout. An inlet ring, flat plate or abrupt edge, guard, fan support, radiator stack and downstream panel can all affect how air approaches or leaves an impeller. Keep the fan build and casing geometry in separate columns so a curve or installed reading stays associated with the actual setup. Name whether the fan draws through the radiator or pushes through it, and include arrows for both airflow and rotation. Note the viewing side for rotation.
UTEK-DELE lists the PMAX3 for agricultural and construction cooling duties. For a corresponding replacement order, review the complete offered assembly and its mounting drawing. Identify the hub plate, mounting face, fastener arrangement, sweep and axial position for the offered build. Mark whether the inlet ring, guard and shroud remain machine-side components or are included in the proposal. A product photograph can help identify which features need documenting. Use the approved assembly drawing for dimensions.

| Mark | What to identify on the sketch | Evidence |
|---|---|---|
| A | Air entry and first obstruction, including screens or nearby panels | Airflow arrows and inlet-side photograph |
| B | Heat-exchanger stack, seals and possible bypass gaps | Radiator and cooler arrangement with component order |
| C | Impeller plane, shroud opening and blade-tip envelope | Side view from a named mounting face |
| D | Guard, supports and nearest downstream obstruction | Exit-side photo and actual measurement basis |
| E | Pressure planes and temperature locations used for comparison | Approved measurement plan naming each station |
Keep rig data and installed data on their own bases
Ask for airflow and the corresponding pressure on the same operating row. Record whether pressure is static or total and which planes define it. A differential taken across the radiator alone describes that component at the recorded flow and condition. It cannot be treated as the same measurement as pressure across the complete fan package. A high free-air value gives no operating-point proof for a particular radiator-and-shroud assembly.
An installation can disturb an otherwise comparable fan test. For example, a close screen or asymmetric inlet may alter the approach flow, while an outlet restriction can change what happens downstream. AMCA’s explanation of fan system effect explains why disturbances near either side matter. Ask the test engineer to identify which installation features are represented on a supplied curve and which will need a matched rig or installed validation. Do not estimate a universal clearance, an airflow gain or a new allowable speed from a photograph.
Use column A for the existing installation or first proposal. Use column B for the second proposal. Put the drawing or test reference next to any value recorded in either column.
| Field and comparison basis | A | B |
|---|---|---|
| Air path ID — mark same or revised ring, core, shroud, guard and outlet revision | — | — |
| Fan build — capture drawing revision, speed, material, pitch reference and rotation view | — | — |
| Operating point — match airflow and pressure basis, station locations, test arrangement and speed | — | — |
| Operating conditions — record ambient/air temperature or density, machine load and radiator condition | — | — |
| Drive and thermal response — state measured shaft or electrical basis, and thermal criteria for the same load and conditions | — | — |
| Open items and release — assign each fit, curve or missing measurement to the responsible reviewer | — | — |
Work through the decision
Scenario A — the fan changes and the air path stays
Use the same approved housing, radiator stack and outlet configuration for the comparison. Document what “same” means, particularly the ring-to-impeller axial relationship and any change in the blade envelope. A closer-fitting layout still needs the machine-approved installation allowances. Request evidence against the required operating point for the offered configuration and keep the variable speed or duty condition fixed. Where the supplier curve used different surroundings, label it as screening data and identify the actual package check needed for release.
Scenario B — the radiator or guard changes at the same time
Treat the changed air path as its own configuration. If a new guard or cooler is introduced, documenting a difference in airflow does not identify which change caused it. When safe and authorized by the equipment owner, request a comparison that isolates the air-path change or records the intervention as a combined retrofit. Keep the old and new station definitions visible. If only one layout has a measured operating point, record the other as awaiting a comparable test. Do not infer a final thermal margin from the catalogue curve alone.
Example — two numbers describe different boundaries
An existing machine log states a pressure drop taken across the radiator at a logged duty. The proposed curve states fan static pressure in a controlled test arrangement. Even if the two numerical pressure values happen to match, they describe different boundaries. Mark the comparison “different basis,” then request the offered curve setup and an approved package measurement plan. If the project needs proof of cooling, agree what load, ambient condition and temperature readings will establish release independently of the airflow check.
Release the configuration with the machine record
Send the same annotated sketch, fan drawing revision and duty sheet to everyone reviewing the proposal. Confirm who owns the installation clearance review, who approves the operating-point comparison and who records the final results. Use the equipment owner's procedures for safe access and testing. Keep the accepted package revision, conditions and test report with the machine tag so repeat orders can be checked for changes in the surrounding hardware as well as the axial impeller.
| Decision | Required record | If the record is missing |
|---|---|---|
| Mechanical fit | Approved assembly drawing and package drawing share a mounting reference and identify the full blade envelope | Keep the fit decision open. Assign the missing interface or envelope detail to the reviewer. |
| Comparable duty | Both proposals give the measurement basis and installation arrangement at the required operating point | Label each unmatched curve as screening evidence and request a matched comparison. |
| Installation and thermal release | Machine owner signs off the applicable site measurements and acceptance criteria | Retain the open issue with the machine tag and the person responsible for closing it. |
Use the engine cooling application page for application context and the axial fan replacement guide when identifying the supply scope of another reference. Share the completed worksheet with the UTEK-DELE application team to request an application review for the offered configuration.