close-img
Industrial Axial Fan Blade Manufacturer | UTEK-DELE Technology Changzhou Co., LtdIndustrial Axial Fan Blade Manufacturer | UTEK-DELE Technology Changzhou Co., Ltd
mobile search button of img
search img of mobile head
    • Home
    • Fan Blades & Components
      mobile img of product plus
      • Fixed-Angle Fan Blades
      • Adjustable-Angle Fan Blades
      • Special & Integrated Fans
      • Air Cooling Systems
      • Equipment
    • Axial Fan
      mobile img of product plus
      • Axial Fan Replacement
    • Applications
      mobile img of cases plus
      • HVAC
      • Engine Cooling
      • Specialist Applications
    • News
      mobile img of news plus
      • Company News
      • Product News
    • Contact
    • Reversible Axial Fan
    • Small Axial Fan Impeller (300-600mm)
    • Medium Axial Fan Blade (500-1100mm)
    • Big Industrial Axial Fan (1000-2200mm)
    • Fixed-Angle Fan Blades
    • Adjustable-Angle Fan Blades
    Industrial Axial Fan Blade Manufacturer | UTEK-DELE Technology Changzhou Co., LtdIndustrial Axial Fan Blade Manufacturer | UTEK-DELE Technology Changzhou Co., Ltd
    admin@utekdele.com0086-13775063485
  • Home
  • Fan Blades & Components
    • Fixed-Angle Fan Blades
    • Adjustable-Angle Fan Blades
    • Special & Integrated Fans
    • Air Cooling Systems
    • Equipment
  • Axial Fan
  • Applications
  • News
  • Contact
  • Get A Quote Now

    • Reversible Axial Fan
      • Pneumatic Reversible Fan
      • Hydraulic Reversible Fan
    • Small Axial Fan Impeller (300-600mm)
      • H Series
      • PMAX Series
      • 4XR Series
    • Medium Axial Fan Blade (500-1100mm)
      • P Series
      • S Series
      • 7Z Series
      • K Series
      • R4Z Series
    • Big Industrial Axial Fan (1000-2200mm)
      • W Series
      • U Series
    • Fixed-Angle Fan Blades
    • Adjustable-Angle Fan Blades
    WHAT ARE YOU LOOKING FOR?
    *
    This field is required
    Total quantity you need
    *
    This field is required
    *
    This field is required
    Email format error
    Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
    This field is required
    Telephone information is wrong!
    Send Message
    Your location:Home  PMAX3 Cooling Package Comparison Worksheet
      • PMAX3 Cooling Package Comparison Worksheet

        Use this worksheet to compare a proposed PMAX3 complete axial fan impeller with an existing cooling assembly or a second proposal for the same machine. The worksheet records the hub and impeller configuration, the surrounding air path and the operating point on one reference sheet. It is intended for an engine or radiator package review, where the same nominal fan diameter can be installed next to very different inlets, cores, guards and outlets.

        Define the comparison before requesting a curveKeep rig data and installed data on their own basesWork through the decisionRelease the configuration with the machine record

        Define the comparison before requesting a curve

        Pick a machine, operating mode and drawing revision. Assign a distinct reference to each air-path layout. An inlet ring, flat plate or abrupt edge, guard, fan support, radiator stack and downstream panel can all affect how air approaches or leaves an impeller. Keep the fan build and casing geometry in separate columns so a curve or installed reading stays associated with the actual setup. Name whether the fan draws through the radiator or pushes through it, and include arrows for both airflow and rotation. Note the viewing side for rotation.

        UTEK-DELE lists the PMAX3 for agricultural and construction cooling duties. For a corresponding replacement order, review the complete offered assembly and its mounting drawing. Identify the hub plate, mounting face, fastener arrangement, sweep and axial position for the offered build. Mark whether the inlet ring, guard and shroud remain machine-side components or are included in the proposal. A product photograph can help identify which features need documenting. Use the approved assembly drawing for dimensions.

        PMAX3 UTEK-DELE complete axial fan impeller product photograph
        UTEK-DELE PMAX3 assembly. The photo identifies the product and central mounting area. Record the shroud and installed dimensions from the machine drawing.
        Air-path sketch labels
        MarkWhat to identify on the sketchEvidence
        AAir entry and first obstruction, including screens or nearby panelsAirflow arrows and inlet-side photograph
        BHeat-exchanger stack, seals and possible bypass gapsRadiator and cooler arrangement with component order
        CImpeller plane, shroud opening and blade-tip envelopeSide view from a named mounting face
        DGuard, supports and nearest downstream obstructionExit-side photo and actual measurement basis
        EPressure planes and temperature locations used for comparisonApproved measurement plan naming each station

        Keep rig data and installed data on their own bases

        Ask for airflow and the corresponding pressure on the same operating row. Record whether pressure is static or total and which planes define it. A differential taken across the radiator alone describes that component at the recorded flow and condition. It cannot be treated as the same measurement as pressure across the complete fan package. A high free-air value gives no operating-point proof for a particular radiator-and-shroud assembly.

        An installation can disturb an otherwise comparable fan test. For example, a close screen or asymmetric inlet may alter the approach flow, while an outlet restriction can change what happens downstream. AMCA’s explanation of fan system effect explains why disturbances near either side matter. Ask the test engineer to identify which installation features are represented on a supplied curve and which will need a matched rig or installed validation. Do not estimate a universal clearance, an airflow gain or a new allowable speed from a photograph.

        Use column A for the existing installation or first proposal. Use column B for the second proposal. Put the drawing or test reference next to any value recorded in either column.

        Comparison worksheet for two proposals
        Field and comparison basisAB
        Air path ID — mark same or revised ring, core, shroud, guard and outlet revision——
        Fan build — capture drawing revision, speed, material, pitch reference and rotation view——
        Operating point — match airflow and pressure basis, station locations, test arrangement and speed——
        Operating conditions — record ambient/air temperature or density, machine load and radiator condition——
        Drive and thermal response — state measured shaft or electrical basis, and thermal criteria for the same load and conditions——
        Open items and release — assign each fit, curve or missing measurement to the responsible reviewer——

        Work through the decision

        Scenario A — the fan changes and the air path stays

        Use the same approved housing, radiator stack and outlet configuration for the comparison. Document what “same” means, particularly the ring-to-impeller axial relationship and any change in the blade envelope. A closer-fitting layout still needs the machine-approved installation allowances. Request evidence against the required operating point for the offered configuration and keep the variable speed or duty condition fixed. Where the supplier curve used different surroundings, label it as screening data and identify the actual package check needed for release.

        Scenario B — the radiator or guard changes at the same time

        Treat the changed air path as its own configuration. If a new guard or cooler is introduced, documenting a difference in airflow does not identify which change caused it. When safe and authorized by the equipment owner, request a comparison that isolates the air-path change or records the intervention as a combined retrofit. Keep the old and new station definitions visible. If only one layout has a measured operating point, record the other as awaiting a comparable test. Do not infer a final thermal margin from the catalogue curve alone.

        Example — two numbers describe different boundaries

        An existing machine log states a pressure drop taken across the radiator at a logged duty. The proposed curve states fan static pressure in a controlled test arrangement. Even if the two numerical pressure values happen to match, they describe different boundaries. Mark the comparison “different basis,” then request the offered curve setup and an approved package measurement plan. If the project needs proof of cooling, agree what load, ambient condition and temperature readings will establish release independently of the airflow check.

        Release the configuration with the machine record

        Send the same annotated sketch, fan drawing revision and duty sheet to everyone reviewing the proposal. Confirm who owns the installation clearance review, who approves the operating-point comparison and who records the final results. Use the equipment owner's procedures for safe access and testing. Keep the accepted package revision, conditions and test report with the machine tag so repeat orders can be checked for changes in the surrounding hardware as well as the axial impeller.

        Evidence to keep at each release decision
        DecisionRequired recordIf the record is missing
        Mechanical fitApproved assembly drawing and package drawing share a mounting reference and identify the full blade envelopeKeep the fit decision open. Assign the missing interface or envelope detail to the reviewer.
        Comparable dutyBoth proposals give the measurement basis and installation arrangement at the required operating pointLabel each unmatched curve as screening evidence and request a matched comparison.
        Installation and thermal releaseMachine owner signs off the applicable site measurements and acceptance criteriaRetain the open issue with the machine tag and the person responsible for closing it.

        Use the engine cooling application page for application context and the axial fan replacement guide when identifying the supply scope of another reference. Share the completed worksheet with the UTEK-DELE application team to request an application review for the offered configuration.

        PMAX3 Cooling Package Comparison Worksheet

        Use this worksheet to compare a proposed PMAX3 complete axial fan impeller with an existing cooling assembly or a second proposal for the same machine. The worksheet records the hub and impeller configuration, the surrounding air path and the operating point on one reference sheet. It is intended for an engine or radiator package review, where the same nominal fan diameter can be installed next to very different inlets, cores, guards and outlets.

        Define the comparison before requesting a curveKeep rig data and installed data on their own basesWork through the decisionRelease the configuration with the machine record

        Define the comparison before requesting a curve

        Pick a machine, operating mode and drawing revision. Assign a distinct reference to each air-path layout. An inlet ring, flat plate or abrupt edge, guard, fan support, radiator stack and downstream panel can all affect how air approaches or leaves an impeller. Keep the fan build and casing geometry in separate columns so a curve or installed reading stays associated with the actual setup. Name whether the fan draws through the radiator or pushes through it, and include arrows for both airflow and rotation. Note the viewing side for rotation.

        UTEK-DELE lists the PMAX3 for agricultural and construction cooling duties. For a corresponding replacement order, review the complete offered assembly and its mounting drawing. Identify the hub plate, mounting face, fastener arrangement, sweep and axial position for the offered build. Mark whether the inlet ring, guard and shroud remain machine-side components or are included in the proposal. A product photograph can help identify which features need documenting. Use the approved assembly drawing for dimensions.

        PMAX3 UTEK-DELE complete axial fan impeller product photograph
        UTEK-DELE PMAX3 assembly. The photo identifies the product and central mounting area. Record the shroud and installed dimensions from the machine drawing.
        Air-path sketch labels
        MarkWhat to identify on the sketchEvidence
        AAir entry and first obstruction, including screens or nearby panelsAirflow arrows and inlet-side photograph
        BHeat-exchanger stack, seals and possible bypass gapsRadiator and cooler arrangement with component order
        CImpeller plane, shroud opening and blade-tip envelopeSide view from a named mounting face
        DGuard, supports and nearest downstream obstructionExit-side photo and actual measurement basis
        EPressure planes and temperature locations used for comparisonApproved measurement plan naming each station

        Keep rig data and installed data on their own bases

        Ask for airflow and the corresponding pressure on the same operating row. Record whether pressure is static or total and which planes define it. A differential taken across the radiator alone describes that component at the recorded flow and condition. It cannot be treated as the same measurement as pressure across the complete fan package. A high free-air value gives no operating-point proof for a particular radiator-and-shroud assembly.

        An installation can disturb an otherwise comparable fan test. For example, a close screen or asymmetric inlet may alter the approach flow, while an outlet restriction can change what happens downstream. AMCA’s explanation of fan system effect explains why disturbances near either side matter. Ask the test engineer to identify which installation features are represented on a supplied curve and which will need a matched rig or installed validation. Do not estimate a universal clearance, an airflow gain or a new allowable speed from a photograph.

        Use column A for the existing installation or first proposal. Use column B for the second proposal. Put the drawing or test reference next to any value recorded in either column.

        Comparison worksheet for two proposals
        Field and comparison basisAB
        Air path ID — mark same or revised ring, core, shroud, guard and outlet revision——
        Fan build — capture drawing revision, speed, material, pitch reference and rotation view——
        Operating point — match airflow and pressure basis, station locations, test arrangement and speed——
        Operating conditions — record ambient/air temperature or density, machine load and radiator condition——
        Drive and thermal response — state measured shaft or electrical basis, and thermal criteria for the same load and conditions——
        Open items and release — assign each fit, curve or missing measurement to the responsible reviewer——

        Work through the decision

        Scenario A — the fan changes and the air path stays

        Use the same approved housing, radiator stack and outlet configuration for the comparison. Document what “same” means, particularly the ring-to-impeller axial relationship and any change in the blade envelope. A closer-fitting layout still needs the machine-approved installation allowances. Request evidence against the required operating point for the offered configuration and keep the variable speed or duty condition fixed. Where the supplier curve used different surroundings, label it as screening data and identify the actual package check needed for release.

        Scenario B — the radiator or guard changes at the same time

        Treat the changed air path as its own configuration. If a new guard or cooler is introduced, documenting a difference in airflow does not identify which change caused it. When safe and authorized by the equipment owner, request a comparison that isolates the air-path change or records the intervention as a combined retrofit. Keep the old and new station definitions visible. If only one layout has a measured operating point, record the other as awaiting a comparable test. Do not infer a final thermal margin from the catalogue curve alone.

        Example — two numbers describe different boundaries

        An existing machine log states a pressure drop taken across the radiator at a logged duty. The proposed curve states fan static pressure in a controlled test arrangement. Even if the two numerical pressure values happen to match, they describe different boundaries. Mark the comparison “different basis,” then request the offered curve setup and an approved package measurement plan. If the project needs proof of cooling, agree what load, ambient condition and temperature readings will establish release independently of the airflow check.

        Release the configuration with the machine record

        Send the same annotated sketch, fan drawing revision and duty sheet to everyone reviewing the proposal. Confirm who owns the installation clearance review, who approves the operating-point comparison and who records the final results. Use the equipment owner's procedures for safe access and testing. Keep the accepted package revision, conditions and test report with the machine tag so repeat orders can be checked for changes in the surrounding hardware as well as the axial impeller.

        Evidence to keep at each release decision
        DecisionRequired recordIf the record is missing
        Mechanical fitApproved assembly drawing and package drawing share a mounting reference and identify the full blade envelopeKeep the fit decision open. Assign the missing interface or envelope detail to the reviewer.
        Comparable dutyBoth proposals give the measurement basis and installation arrangement at the required operating pointLabel each unmatched curve as screening evidence and request a matched comparison.
        Installation and thermal releaseMachine owner signs off the applicable site measurements and acceptance criteriaRetain the open issue with the machine tag and the person responsible for closing it.

        Use the engine cooling application page for application context and the axial fan replacement guide when identifying the supply scope of another reference. Share the completed worksheet with the UTEK-DELE application team to request an application review for the offered configuration.

        Recommended Products

        PMAX3 High-Pressure Axial Fan Impeller for Agricultural and Construction Applications
        PMAX Series

        PMAX3 High-Pressure Axial Fan Impeller for Agricultural and Construction Applications

        ModelPMAX3

        News and Articles

        img of Engine Cooling Fans: Lightweight Blade Solutions for Automotive and Industrial Engines

        Engine Cooling Fans: Lightweight Blade Solutions for Automotive and Industrial Engines

        An engine cooling fan must be matched to the radiator, shroud, drive and thermal operating conditions. This guide reviews UTEK-DELE blade materials and reversible systems, including ALU’s documented −40 to 150°C material range, without inventing cooling or fuel-saving ratings.
        View More
        • Quick LinksProductsApplicationsNews
        • Main ProductsReversible FanSmall FanMedium FanBig FanAir Cooling SystemsEquipment
        • ApplicationsHVACEngine CoolingOther
        • Contact Us

          13775063485

          0086-13775063485

          admin@utekdele.com

          No.120, TaihuEast Road, Sanjing Street, Xinbei District, Changzhou, Jiangsu, China

        CopyRight © 2026 - UTEK-DELE Technology Changzhou Co., Ltd  All rights reserved  Sitemap   All tags   Designed by Zhonghuan Internet
        Contact
        0086-13775063485
        admin@utekdele.com
        13775063485
        To Top

        • Tel

        • E-mail

        • Contact